## Purpose
|
|
This document describes the **end-to-end procedure** for creating a **thick-provisioned iSCSI-backed shared storage target** on **TrueNAS CORE**, and consuming it from a **Proxmox VE cluster** using **shared LVM**.
|
|
|
|
This approach is intended to:
|
|
|
|
- Provide SAN-style block semantics
|
|
- Enable Proxmox-native snapshot functionality (LVM volume chains)
|
|
- Avoid third-party plugins or middleware
|
|
- Be fully reproducible via CLI
|
|
|
|
## Assumptions
|
|
- TrueNAS **CORE** (not SCALE)
|
|
- ZFS pool already exists and is healthy
|
|
- SSH service is enabled on TrueNAS
|
|
- Proxmox VE nodes have network connectivity to TrueNAS
|
|
- iSCSI traffic is on a reliable, low-latency network (10GbE recommended)
|
|
- All VM workloads are drained from at least one Proxmox node for maintenance
|
|
|
|
!!! note "Proxmox VE Version Context"
|
|
This guide assumes **Proxmox VE 9.1.4 (or later)**. Snapshot-as-volume-chain support on shared LVM (e.g., iSCSI) is available and improved, including enhanced handling of vTPM state in offline snapshots.
|
|
|
|
!!! warning "Important"
|
|
`volblocksize` **cannot be changed after zvol creation**. Choose carefully.
|
|
|
|
## Target Architecture
|
|
|
|
```
|
|
ZFS Pool
|
|
└─ Zvol (Thick / Reserved)
|
|
└─ iSCSI Extent
|
|
└─ Proxmox LVM PV
|
|
└─ Shared VG
|
|
└─ VM Disks
|
|
```
|
|
|
|
## Create a Dedicated Zvol for Proxmox
|
|
|
|
### Variables
|
|
Adjust as needed before execution.
|
|
|
|
```sh
|
|
POOL_NAME="CLUSTER-STORAGE"
|
|
ZVOL_NAME="iscsi-storage"
|
|
ZVOL_SIZE="14T"
|
|
VOLBLOCKSIZE="16K"
|
|
```
|
|
|
|
### Create the Zvol (Thick-Provisioned)
|
|
```sh
|
|
zfs create -V ${ZVOL_SIZE} \
|
|
-o volblocksize=${VOLBLOCKSIZE} \
|
|
-o compression=lz4 \
|
|
-o refreservation=${ZVOL_SIZE} \
|
|
${POOL_NAME}/${ZVOL_NAME}
|
|
```
|
|
|
|
!!! note
|
|
The `refreservation` enforces **true thick provisioning** and prevents overcommit.
|
|
|
|
## Configure iSCSI Target (TrueNAS CORE)
|
|
|
|
This section uses a **hybrid approach**:
|
|
- **CLI** is used for ZFS and LUN (extent backing) creation
|
|
- **TrueNAS GUI** is used for iSCSI portal, target, and association
|
|
- **CLI** is used again for validation
|
|
|
|
### Enable iSCSI Service
|
|
|
|
```sh
|
|
service ctld start
|
|
sysrc ctld_enable=YES
|
|
```
|
|
|
|
### Create the iSCSI LUN Backing (CLI)
|
|
This step creates the **actual block-backed LUN** that will be exported via iSCSI.
|
|
|
|
```sh
|
|
# Sanity check: confirm the backing zvol exists
|
|
ls -l /dev/zvol/${POOL_NAME}/${ZVOL_NAME}
|
|
|
|
# Create CTL LUN backed by the zvol
|
|
ctladm create -b block \
|
|
-o file=/dev/zvol/${POOL_NAME}/${ZVOL_NAME} \
|
|
-S ISCSI-STORAGE \
|
|
-d ISCSI-STORAGE
|
|
```
|
|
|
|
### Verify the LUN is real and correctly sized
|
|
|
|
```sh
|
|
ctladm devlist -v
|
|
```
|
|
|
|
!!! tip
|
|
`Size (Blocks)` must be **non-zero** and match the zvol size. If it is `0`, stop and correct before proceeding.
|
|
|
|
### Configure iSCSI Portal, Target, and Extent Association (CLI Only)
|
|
|
|
!!! warning "Do NOT Use the TrueNAS iSCSI GUI"
|
|
**Once you choose a CLI-managed iSCSI configuration, the TrueNAS Web UI must never be used for iSCSI.**
|
|
Opening or modifying **Sharing → Block Shares (iSCSI)** in the GUI will **overwrite CTL runtime state**, invalidate manual `ctladm` configuration, and result in targets that appear correct but expose **no LUNs** to initiators.
|
|
|
|
**This configuration is CLI-owned and CLI-managed.**
|
|
|
|
- Do **not** add, edit, or view iSCSI objects in the GUI
|
|
- Do **not** use the iSCSI wizard
|
|
- Do **not** mix GUI extents with CLI-created LUNs
|
|
|
|
#### Create iSCSI Portal (Listen on All Interfaces)
|
|
|
|
```sh
|
|
# Backup any existing ctl.conf
|
|
cp -av /etc/ctl.conf /etc/ctl.conf.$(date +%Y%m%d-%H%M%S).bak 2>/dev/null || true
|
|
|
|
# Write a clean /etc/ctl.conf
|
|
cat > /etc/ctl.conf <<'EOF'
|
|
# --- Bunny Lab: Proxmox iSCSI (CLI-only) ---
|
|
auth-group "no-auth" {
|
|
auth-type none
|
|
initiator-name "iqn.1993-08.org.debian:01:5b963dd51f93" # cluster-node-01 ("cat /etc/iscsi/initiatorname.iscsi")
|
|
initiator-name "iqn.1993-08.org.debian:01:1b4df0fa3540" # cluster-node-02 ("cat /etc/iscsi/initiatorname.iscsi")
|
|
initiator-name "iqn.1993-08.org.debian:01:5669aa2d89a2" # cluster-node-03 ("cat /etc/iscsi/initiatorname.iscsi")
|
|
}
|
|
|
|
# Listen on all interfaces on the default iSCSI port
|
|
portal-group "pg0" {
|
|
listen 0.0.0.0:3260
|
|
discovery-auth-group "no-auth"
|
|
}
|
|
|
|
# Create a target IQN
|
|
target "iqn.2026-01.io.bunny-lab:storage" {
|
|
portal-group "pg0"
|
|
auth-group "no-auth"
|
|
|
|
# Export LUN 0 backed by the zvol device
|
|
lun 0 {
|
|
path /dev/zvol/CLUSTER-STORAGE/iscsi-storage
|
|
serial "ISCSI-STORAGE"
|
|
device-id "ISCSI-STORAGE"
|
|
}
|
|
}
|
|
EOF
|
|
|
|
# Restart ctld to apply the configuration file
|
|
service ctld restart
|
|
|
|
# Verify the iSCSI listener is actually up
|
|
sockstat -4l | grep ':3260'
|
|
|
|
# Verify CTL now shows an iSCSI frontend
|
|
ctladm portlist -v | egrep -i '(^Port|iscsi|listen=)'
|
|
```
|
|
|
|
!!! success
|
|
At this point, the iSCSI target is live and correctly exposing a block device to initiators. You may now proceed to **Connect from ProxmoxVE Nodes** section.
|
|
|
|
## Connect from ProxmoxVE Nodes
|
|
Perform the following **on each Proxmox node**.
|
|
|
|
```sh
|
|
# Install iSCSI Utilities
|
|
apt update
|
|
apt install -y open-iscsi lvm2
|
|
|
|
# Discover Target
|
|
iscsiadm -m discovery -t sendtargets -p <TRUENAS_IP>
|
|
|
|
# Log In
|
|
iscsiadm -m node --login
|
|
|
|
# Rescan SCSI Bus
|
|
iscsiadm -m session -P 3
|
|
|
|
### Verify Device
|
|
# If everything works successfully, you should see something like "sdi 8:128 0 8T 0 disk".
|
|
lsblk
|
|
```
|
|
|
|
## Create Shared LVM (Execute on One Node Only)
|
|
|
|
!!! warning "Important"
|
|
**Only run LVM creation on ONE node**. All other nodes will only scan.
|
|
|
|
```sh
|
|
# Initialize Physical Volume
|
|
pvcreate /dev/sdX
|
|
|
|
# Create Volume Group
|
|
vgcreate vg_proxmox_iscsi /dev/sdX
|
|
```
|
|
|
|
## Register Storage in Proxmox
|
|
### Rescan LVM (Other Nodes)
|
|
```sh
|
|
pvscan
|
|
vgscan
|
|
```
|
|
|
|
### Add Storage (GUI)
|
|
**Datacenter → Storage → Add → LVM**
|
|
|
|
- ID: `iscsi-cluster-lvm`
|
|
- Volume Group: `vg_proxmox_iscsi`
|
|
- Content: `Disk image, Container`
|
|
- Shared: ✔️
|
|
- Allow Snapshots as Volume-Chain: ✔️
|
|
|
|
## Validation
|
|
|
|
- Snapshot create / revert / delete
|
|
- Live migration between nodes
|
|
- PBS backup and restore test
|
|
|
|
!!! success
|
|
If all validation tests pass, the storage is production-ready.
|
|
|
|
## Expanding iSCSI Storage (No Downtime)
|
|
If you need to expand the storage space of the newly-created iSCSI LUN, you can run the ZFS commands seen below on the TrueNAS Core server. The first command increases the size, the second command pre-allocated the space (thick-provisioned).
|
|
|
|
!!! warning "ProxmoxVE Cluster-specific Notes"
|
|
|
|
- `pvresize` must be executed on **exactly one** ProxmoxVE node.
|
|
- All other nodes should only perform `pvscan` / `vgscan` after the resize.
|
|
- Running `pvresize` on multiple nodes can corrupt shared LVM metadata.
|
|
|
|
```sh
|
|
# Expand Zvol (TrueNAS)
|
|
zfs set volsize=16T CLUSTER-STORAGE/iscsi-storage
|
|
zfs set refreservation=16T CLUSTER-STORAGE/iscsi-storage
|
|
service ctld restart
|
|
|
|
# Rescan the block device on all ProxmoxVE nodes
|
|
echo 1 > /sys/class/block/sdX/device/rescan
|
|
|
|
# Verify on all nodes that the new size is displayed
|
|
lsblk /dev/sdX
|
|
|
|
# Run this on only ONE of the ProxmoxVE nodes.
|
|
pvresize /dev/sdX
|
|
|
|
# Rescan on the other nodes that you did not run the pvresize command on. They will now see the expanded free space.
|
|
pvscan
|
|
vgscan
|
|
``` |