		| @@ -4,6 +4,7 @@ When you migrate virtual machines from Hyper-V (and possibly other platforms) to | ||||
|  | ||||
| ### Fixing Boot Issues | ||||
| Some high-level things to do to fix this are listed below: | ||||
|  | ||||
| - Switch the VM processor type to `host`. | ||||
| - The socket and core counts are reversed, so a single socket CPU with 16 cores will appear like 16 sockets with one core each, flip these around to correct this issue. | ||||
| - The storage controller needs to be set to `VirtIO iSCSI` | ||||
| @@ -11,6 +12,7 @@ Some high-level things to do to fix this are listed below: | ||||
|  | ||||
| #### Dracut Emergency Shell | ||||
| If you start the VM and you reach a "dracut" prompt, then the bootloader got nuked and needs to be regenerated.  Follow the steps below to work through this process: | ||||
|  | ||||
| - Boot from a Rocky Linux 9.5+ installation ISO in the broken Rocky Linux VM | ||||
| - Select "**Troubleshooting -->**" in the boot menu | ||||
| - Select "**Rescue a Rocky Linux System**" | ||||
| @@ -28,6 +30,7 @@ exit | ||||
|  | ||||
| ### Fixing Network Issues | ||||
| The VM will lose the adapter name of `eth0` and put something else like `ens18` that needs to be reconfigured manually to get networking functional again: | ||||
|  | ||||
| - Type `ethtool ens18`, and if the link speed is `Unknown!`, then poweroff the VM and switch the network adapter from `VirtIO (paravirtualized)` to `Intel E1000`, then boot the VM back up. | ||||
| - Run the following commands to assign the new `ens18` interface as a networking interface for the VM to use: | ||||