Continued WireGuard troubleshooting
This commit is contained in:
106
Docs/Codex/WireGuard_Troubleshooting.md
Normal file
106
Docs/Codex/WireGuard_Troubleshooting.md
Normal file
@@ -0,0 +1,106 @@
|
||||
# Borealis WireGuard Troubleshooting Handoff
|
||||
|
||||
This file is a self-contained handoff prompt + context for a new Codex agent to resume WireGuard tunnel troubleshooting.
|
||||
|
||||
## Prompt to Use in a New Codex Session
|
||||
|
||||
Copy/paste the prompt below into a new Codex chat:
|
||||
|
||||
"""
|
||||
You are a new Codex agent working in d:\Github\Borealis. Please do the following:
|
||||
|
||||
1) Read AGENTS.md, Docs/Codex/BOREALIS_AGENT.md, Docs/Codex/BOREALIS_ENGINE.md, Docs/Codex/REVERSE_TUNNELS.md, then Docs/Codex/WireGuard_Troubleshooting.md.
|
||||
2) Investigate why the WireGuard tunnel does not come up (remote shell timeouts) even though the Engine emits vpn_tunnel_start.
|
||||
3) Focus on the WireGuard client lifecycle in Data/Agent/Roles/role_WireGuardTunnel.py and the bootstrap logic in Borealis.ps1 (WireGuard adapter provisioning).
|
||||
4) Use Data/Agent for edits (runtime under Agent/ is ephemeral). Keep the adapter name "Borealis" and ensure idempotent behavior. Do not rely on the PIA adapter.
|
||||
5) Provide concrete fixes + verification steps. Be careful with Windows services and avoid GUI popup dialogs when possible.
|
||||
"""
|
||||
|
||||
## Environment / Scope
|
||||
|
||||
- Workspace: d:\Github\Borealis
|
||||
- Host OS: Windows 10/11 (build 26200). Current tests run on the Windows 11 machine that also runs Engine + Agent.
|
||||
- Agent/Engine launch: via Borealis.ps1, always elevated as admin.
|
||||
- Network: Engine + Agent run on the same host during testing (Engine endpoint is "localhost:30000").
|
||||
- WireGuard version: wireguard.exe 0.5.3, wg.exe 1.0.20210914.
|
||||
- PIA (Private Internet Access) is installed and supplies a wintun driver (pia-wintun.sys). Do NOT treat the PIA adapter as the Borealis adapter.
|
||||
|
||||
## Desired Behavior
|
||||
|
||||
- Agent has a dedicated WireGuard adapter named "Borealis" (Description shows "WireGuard Tunnel").
|
||||
- Adapter provisioning is idempotent: if "Borealis" exists, do not recreate it.
|
||||
- WireGuard config should be stored under Agent\Borealis\Settings\WireGuard\Borealis.conf (preferred) and not only in Program Files.
|
||||
- Agent should bring up the WireGuard tunnel on vpn_tunnel_start, then remote shell / RDP / VNC / SSH should flow through it.
|
||||
- On stop/idle, the tunnel should be torn down and firewall rules removed.
|
||||
|
||||
## Recent Changes (Current Repo State)
|
||||
|
||||
- Data/Agent/Roles/role_WireGuardTunnel.py
|
||||
- Service name fix: WireGuard tunnel service is "WireGuardTunnel$Borealis".
|
||||
- Config path preference: Agent\Borealis\Settings\WireGuard.
|
||||
- Uses registry ImagePath to locate the actual service config when needed.
|
||||
- Adds a session lock to prevent concurrent start/stop.
|
||||
- Borealis.ps1
|
||||
- WireGuard config search order includes Agent\Borealis\Settings\WireGuard.
|
||||
- Adapter provisioning reads the service ImagePath to write config when service exists.
|
||||
- Avoids /installtunnelservice if service still present to prevent GUI error dialogs.
|
||||
- Adapter name is "Borealis".
|
||||
|
||||
Note: Data/Agent changes only apply to runtime after Borealis.ps1 re-stages the agent under Agent/.
|
||||
|
||||
## Symptoms from Fresh Logs (2026-01-12 19:29)
|
||||
|
||||
Agent (Agent/Logs/VPN_Tunnel/tunnel.log):
|
||||
- "WireGuard tunnel service already installed; skipping install."
|
||||
- "WireGuard tunnel service still missing after install attempt."
|
||||
|
||||
Engine (Engine/Logs/VPN_Tunnel/tunnel.log):
|
||||
- vpn_tunnel_session_create for agent LAB-OPERATOR-01_..._SYSTEM
|
||||
- WireGuard listener installed (service=borealis-wg)
|
||||
- vpn_api_status_response status=up
|
||||
|
||||
Engine (Engine/Logs/VPN_Tunnel/remote_shell.log):
|
||||
- repeated vpn_shell_connect_attempt to 10.255.0.2:47002
|
||||
- timeouts
|
||||
|
||||
Agent (Agent/Logs/VPN_Tunnel/remote_shell.log):
|
||||
- VPN shell server listening on 0.0.0.0:47002
|
||||
|
||||
Net effect: engine believes tunnel is "up", but remote shell cannot reach 10.255.0.2. This implies the WireGuard client tunnel is not actually up on the agent.
|
||||
|
||||
## Key Paths
|
||||
|
||||
- Agent WireGuard role: Data/Agent/Roles/role_WireGuardTunnel.py
|
||||
- Agent VPN shell role: Data/Agent/Roles/role_VpnShell.py
|
||||
- Engine WireGuard manager: Data/Engine/services/VPN/wireguard_server.py
|
||||
- Engine tunnel service: Data/Engine/services/VPN/vpn_tunnel_service.py
|
||||
- Agent tunnel logs: Agent/Logs/VPN_Tunnel/tunnel.log
|
||||
- Agent shell logs: Agent/Logs/VPN_Tunnel/remote_shell.log
|
||||
- Engine tunnel logs: Engine/Logs/VPN_Tunnel/tunnel.log
|
||||
- Engine shell logs: Engine/Logs/VPN_Tunnel/remote_shell.log
|
||||
- Agent WireGuard config: Agent/Borealis/Settings/WireGuard/Borealis.conf
|
||||
|
||||
## Known WireGuard Services / Names
|
||||
|
||||
- Engine listener service name: "borealis-wg"
|
||||
- Agent tunnel service name: "WireGuardTunnel$Borealis"
|
||||
- Adapter name in Control Panel: "Borealis"
|
||||
|
||||
## Suggested Verification Commands
|
||||
|
||||
- Check agent service:
|
||||
- Get-Service -Name "WireGuardTunnel$Borealis"
|
||||
- Get-ItemProperty "HKLM:\\SYSTEM\\CurrentControlSet\\Services\\WireGuardTunnel$Borealis" | Select-Object ImagePath
|
||||
- Confirm adapter exists:
|
||||
- Get-NetAdapter -IncludeHidden | Where-Object { $_.InterfaceDescription -like "*WireGuard*" } | Select-Object Name, Status, InterfaceDescription, ifIndex
|
||||
- Check WireGuard state:
|
||||
- "C:\\Program Files\\WireGuard\\wg.exe" show
|
||||
|
||||
## Troubleshooting Focus Areas
|
||||
|
||||
- Ensure runtime is up-to-date (Borealis.ps1 re-staging Data/Agent -> Agent/).
|
||||
- Validate service detection vs. WireGuard install output (sc.exe vs registry).
|
||||
- Confirm the config file used by the service matches Agent/Borealis/Settings/WireGuard/Borealis.conf.
|
||||
- Confirm /installtunnelservice is not invoked when service already exists (avoid WireGuard GUI errors).
|
||||
- Confirm the WireGuard tunnel actually connects (wg.exe show handshake) before attempting remote shell.
|
||||
|
||||
Reference in New Issue